Engineering & Application Overview
Ventilation & Climate Control
Poultry-house ventilation and evaporative cooling equipment manages air exchange, air speed, heat and humidity according to bird load and climate.

IX-VENTILATION-COOLING is an IXORTA poultry ventilation and cooling. Poultry-house ventilation and evaporative cooling equipment manages air exchange, air speed, heat and humidity according to bird load and climate. Its principal catalogue values are Catalogue fan size: 96 × 96 cm; Fan motor: 0.5 HP.
Start with the IXORTA Poultry & Feed product range, then use this model page to assess fit, operating needs and the information required for a quotation.
IXORTA manufactures specialized industrial configurations engineered in Konya, Türkiye for duty performance, high reliability, and turnkey automation. Explore specific machine types below:
Ventilation & Climate Control
Ventilation & Climate Control
Ventilation & Climate Control
Ventilation & Climate Control
Ventilation & Climate Control
Ventilation & Climate Control
The values below come from the supplied 2026 IXORTA catalogue.
The values below come from the supplied 2026 IXORTA catalogue. Use them to build an initial shortlist, then confirm the exact configuration, options and acceptance criteria in the model-specific quotation.
| Catalogue fan size | 96 × 96 cm |
|---|---|
| Fan motor | 0.5 HP |
| Fan blades | 6 stainless blades |
| Air inlet | 61 × 37 cm catalogue example |
| Cooling-pad heights | 60–200 cm options |
| Pad thickness | 10 or 15 cm |
Before ordering: confirm the duty, usable capacity, overall dimensions, utilities, safety package, controls, attachments and documentation for the destination market. Download the division catalogue.
IX-VENTILATION-COOLING sits between the smaller and larger configurations in this 7-model range, making side-by-side spe...
IX-VENTILATION-COOLING sits between the smaller and larger configurations in this 7-model range, making side-by-side specification comparison especially important.
Shortlist this model when the planned duty is close to its listed values. If the application regularly approaches a limit, compare the adjacent models below and ask IXORTA to check working margin, cycle expectations and future capacity.
Fans create controlled airflow through inlets and, when required, wet cooling pads.
Fans create controlled airflow through inlets and, when required, wet cooling pads. The control system stages equipment from sensor readings while emergency ventilation protects the flock during faults.
The safe sequence depends on the supplied guards, controls, utilities and attachments. Operators should follow the delivered manual, training and site risk assessment. For process examples and planning articles, continue to the IXORTA Poultry & Feed industry guides.
Review fan frames and guards, motor and blade balance, inlet operation, cooling-pad frame and water distribution, sensor...
Review fan frames and guards, motor and blade balance, inlet operation, cooling-pad frame and water distribution, sensors, controls and airflow tests.
A useful factory-acceptance record identifies the agreed configuration, principal components, inspection points, test material or load, observed results, open actions, documentation set, packing method and release approval. See IXORTA Poultry & Feed project scopes for the wider delivery context.
A catalogue capacity alone is not enough.
A catalogue capacity alone is not enough. IXORTA should receive the normal and peak operating range, site conditions, utilities, operator experience, destination and delivery constraints before recommending a configuration. Review the division buyer FAQs before sending the enquiry.
Use the project enquiry form to identify any required training, commissioning or operator documentation.
Use the project enquiry form to identify any required training, commissioning or operator documentation.
Intervals depend on operating hours, duty, dust, heat, water quality and the surrounding environment.
Intervals depend on operating hours, duty, dust, heat, water quality and the surrounding environment. The delivered manual and component schedules control the final service plan. Send spare-parts and service questions through the IXORTA contact page.
Confirm bird type and age, house dimensions, summer design temperature, power and water reliability, ventilation duty, f...
Confirm bird type and age, house dimensions, summer design temperature, power and water reliability, ventilation duty, feed storage, emergency operation, automation level, biosecurity, inland route and installation responsibilities.
For a useful export quotation, include the destination port, inland route, unloading equipment, site access, local standards, document language, commissioning responsibility and critical spare-parts expectation. Browse regional project examples.
Send the intended application, capacity, destination and site conditions. The request is routed to the IXORTA team with this division and model already identified.
Direct engineering answers on durability, climate adaptation, maintenance, and factory delivery from IXORTA in Konya, Türkiye.
Poultry-house ventilation and evaporative cooling equipment manages air exchange, air speed, heat and humidity according to bird load and climate. Typical applications include hot-climate layer houses, broiler tunnel ventilation, rearing houses, breeder projects.
Fans create controlled airflow through inlets and, when required, wet cooling pads. The control system stages equipment from sensor readings while emergency ventilation protects the flock during faults.
Catalogue fan size is 96 × 96 cm; Fan motor is 0.5 HP; Fan blades is 6 stainless blades; Air inlet is 61 × 37 cm catalogue example; Cooling-pad heights is 60–200 cm options; Pad thickness is 10 or 15 cm. These are catalogue-listed reference values and must be confirmed in the final quotation.
Send the application, required capacity, materials or operating conditions, utilities, destination country and port, site constraints, preferred options, project timing and installation expectations.
The agreed configuration, safety equipment, dimensions, utilities, documentation, factory acceptance scope, packing, spare-parts list, installation responsibilities and destination requirements should be recorded before release.
Yes. IXORTA poultry systems are engineered with heavy-duty thermal insulation, oversized tunnel ventilation cone fans, evaporative cellulose cooling pads, and longitudinal manure drying air ducts to ensure full animal welfare in ambient temperatures exceeding 48°C.
All structural uprights, tier frames, and floor mesh are fabricated from high-tensile steel hot-dip galvanized with 275 g/m² zinc coating conforming to ISO 1461, ensuring complete resistance against organic ammonia and sanitizing detergents for 15–20 years.
Standard commercial configurations are manufactured and quality-verified within 4 to 6 weeks. Components are strapped, cushioned, moisture-barrier sealed, and loaded into 40ft High-Cube sea containers for secure international transit.
Yes. Factory mechanical and electrical installation supervisors are dispatched to customer project sites worldwide to oversee assembly, wire automation panels, commission drive units, and train farm personnel.
Every installation includes a comprehensive 2-year consumable spare parts package and a 24-month manufacturer structural warranty. Emergency replacement parts are stocked in Konya and dispatched worldwide via express air courier within 48 hours.
Use the enquiry form above, email the technical brief or continue by WhatsApp.